Features
  • Parameters Three Parameters SPO2 TEMP Pulse Rate.
  • Waveforms SPO2 waveform-PLETH
  • Compact, small, light, and easy for carrying and handling
  • LCD display of measurement and LCD display of PLETH
  • Audio and visual alarm
  • Storage and review of patient’s trend data up to 36 hours which is never lost even when power’s off
  • Three kinds of power supply, AC Power, Build-in rechargeable Ni/MH battery and Common AA alkaline or rechargeable batteries
  • Battery capacity indicator
  • Automatic power-off
  • Patient’s trend can be transmitted to a personal computer for display,saving and printing
  • Suitable for adult, pediatric, and neonate patients


Table Pulse Oximeter can be applied in the hospital’s operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment.

Technical Specification

1.General
Monitoring Parameters :
SpO2 PRPLETH Pulse strength TEMP(Optional) Signal sockets SpO2 socketPR socketTEMPsocket (Optional) adaptor socket PC communication socket Display screen

Type : 128×64 dot matrix homochromy LCD and Dual-color LED (red/green)
LCD Display Area : 46mm×32mm
LED Display Area : 35mm×58mm
White
LED : Dual-color LED (red/green) and homochromy LED

2. Features

PLETH :
The monitor can display PLETH waveform Audio and visual alarm: The speaker sounds the alarm and the parameter’s measurement flashes on the screen.
Prompting : Icons of battery capacity, pulse sound switch and alarm sound switch.
Power Saving : The monitor will automatic shut down when no monitoring for 3 minutes.
Trend : The monitor saves parameter measurements every 2 seconds and can store trend data up to 36 hours.
Data Storage : The saved data will never be lost even if the monitor is powered off.
Communication : Transmitting the patient’s trend to a PC for display, observation, saving and printing.

3. Electrical Specifications
Working Voltage :
DC 6.0V9.0VAC power adaptor
Input : AC 100240V, 50/60Hz, 0.7A
Output : DC 5V3AInternal battery
Type : 1.5Ahr/8.4V Li rechargeable battery
Run Time : 15-hour continuous operation with a new, fully charged battery (environment temperature is 25C)
Recharge Time : 5 hours Common 1.5V Battery
Type : Five pieces of common 1.5V AA battery or rechargeable battery
Run Time : More than 5-hour continuous operation with a new battery (environment temperature is 25C)

4. Environment
Temperature :
Operation 0°C ~ 45 °C
Transportation and Storage : -20 °C ~ 60 °C
Humidity : Operation15% ~95 %(non-condensing)
Transportation and Storage : 10% ~ 95 % (non-condensing)
Altitude Operation : 86KPa~106KPa
Transportation and Storage : 50KPa~106KPa

5. Parameter Specifications
SpO2 Patient :
Adult, child and neonate
Range : 35%~100%
Resolution : 1 %
Accuracy : ±2 %(70% ~100%), Unspecified (0%~ 69%)
PR Range : 30 bpm~250bpm
Resolution : 1bpm
Accuracy : ±2bpm
TEMP Channel : 1
Input : Body surface thermal-sensitive resistor temperature sensor
Range : 0C50C
Resolution : 0.1C
Accuracy : ±0.2C
Dimension : 160mm×148mm×85mm

Specification
  • Digital Technology
  • Alarm with freely set limit
  • Accurate measurement during low perfusion
  • Power-Saved Function
  • Anti-Movement, Stable Performance
  • Bright, Easy-to-Read LED Numerals
  • Lightweight, Portable
  • 2 parameters: SPO2 + Pulse Rate





 