Specification :

Magnet System :
  • You can choose any of the following magnet types: 0.2T, 0.3T, 0.35T, 0.4T, 0.5T open MRI systems)
  • Open Permanent magnet, eddy current free & self-temperature control
  • Self-temperature control system
  • Shell
  • Locating system

Magnet :
  • Type: Permanent magnet, eddy current free, open C type & self-temperature control
  • Field homogeneity: <±2ppm(FWHH)/20cm DSV <5ppm(VRMS)/40cm DSV
  • Active shim: <±1ppm(FWHH)/20cm spherical surface DSV <±2ppm(VRMS)/40cm spherical surface DSV
  • Vertical gap distance: 40cm

Image specifications :
Image types: T1 weighted image, T2 weighted image, T2* weighted image, PD weighted
image, diffusion weighted image, fat suppressed image, water suppressed image,
Magnetic resonance hygrography (MRCP MRM MRU), MRA
Field of view: 40mm-400mm
Acquisition matrix: 64x64-512x512
Graphics matrix max.: 1024x1024
Body in 30cm FOV: 1.5mm
Head in 24cm FOV: 1mm

Orientation :
Slice orientation: transverse, sagittal, coronal, free oblique, multi-slice & multi-range
Slice gap: 0-20mm

Auto pre-scan function :
Auto RF correction, auto frequency lock, auto gain, auto coil identification, auto coil
tuning, active shim

RF transmitting & receiving system :
  • Type of transmitter & receiver: Digital
  • Frequency range: DC-22MHZ
  • Maximum receiver bandwidth: 1.25MHZ
  • Pre-amplifier: gain 30dB
  • Noise figure: 0.3dB
  • RF amplifier: ≥6kw

Gradient system :

Amplifier :
  • Field strength: single axis 15mT/m, effective 25.9mT/m
  • Slew rate: single axis 50mT/m/ms, effective 86mT/m/ms
  • Linearity: 40cm*40cm*38cm ellipsoid<5%

Receiving system :
  • Head, Body (big), Body (small), Neck, Knee, Shoulder, Wrist coil each

Gradient System :
  • Gradient amplifier
  • X Y Z gradient coil

Patient System :
  • Patient table
  • Doctor-patient communication system

Computer System :
  • DELL imaging workstation
  • dual-core processor (≥ 2.8GHz), Graphics memory: 128MB, Memory: 2 GB, Hard driver: 160 GB, Removable storage: CD+RW, 21” TFT monitor with at least 1280x1024resolution
  • Console table

Software Package :
  • The MRI system software, including: Field homogeneity package, Basic imaging sequence package, system controlling package, Data processing package, Image reconstruction package, image processing and analysis package, Self-default analysis package, Hydrography image package, Angiography image package, Diffusion image package and Laser camera communication package (DICOM 3.0)

Pulse sequence :
  • Spin echo (SE)
  • Multi-slice & Multi-echo (MSME)
  • Fast Spin Echo (FSE)
  • Single shot fast spin echo (SSFSE)
  • Multi shot fast spin echo (MSFSE)
  • Inversion recovery (IR)
  • Short inversion tau IR (STIR)
  • Fluid attenuated IR (FLAIR): T1W, T2W
  • Inversion recovery fast spin echo (IRFSE)
  • Gradient echo (GRE): 2D/3D
  • Steady state process GRE (SSPGRE)
  • MRA: TOF 2D/3D
  • Echo Planar Imaging (EPI)

Image display & post processing :
  • Image post processing: filter, zoom, cut, text illustration & elimination, image offset, auto adjustment of window length & width
  • Image analysis: interested area illustration, distance measurement

Accessories :
  • Mattress, Pillows, testing samples, warning signs

Option systems :
  • 0.2T
  • 0.3T
  • 0.35T
  • 0.4T
  • 0.5T

Coils :
  • Head, Body (big), Body (small), Neck, Knee, Shoulder, Wrist coil each, …etc








 