MM-C003 Mother Fetal Monitor

Products Patient Monitor System MM-C003 Mother Fetal Monitor


MM-C003 Mother Fetal Monitor
Specifications:

Performance

  • This mother/fetal monitor can monitor end-tidal carbon dioxide, blood pressure.


  • Spo2, temperature, pulse, respiration, uterine contraction pressure, fetal quickening and fetal heart rate.


  • Applies modularized design. Different monitoring parameter can be.

  • chosen according to user’s needs to form the user’s own monitor.


Fetal Heart Rate

  • Method of measurement : Ultrasonic Doppler

  • Measuring range: 65~210 bpm

  • Measurement error: ≤±2 bpm

  • Working of ultrasound: impulse wave

  • Alarm range: upper limit : 22bpm~200bpm

  • Lower limit: 180bpm~248bpm


Uterine Contraction Pressure:

 
  • Method of measurement : external method

  • Measuring range:0~100 unit

  • Measurement error: ≤±10%


  • Quickening Sign:

     
    • Manual and aut


    ECG

    • Method of measurement : 25bpm~230bpm

    • Measurement error: ≤±5%

    • Lead: 7 leads

    • Gain: ×0.5, ×1, ×2,

    • Alarm range: upper limit: 30bpm~230bpm, Lower limit: 20bpm~120bpm

                                    
    SpO2

    • Method of measurement :60%~90%

    • Resolution: 1%

    • Measurement error: ≤±2% (90%~99%), ≤±4% (70%~89%), ≤±6% (60%~69%)
    •  
    • Alarm range: Upper limit : 70%~99%, Lower limit: 60%~98%


    NIBP

    • Method of measurement :automatic surging method
    • Working mode: manual/auto

    • Interval of auto measuring mode: 1251015203045, 6090120150180210240min
    •  
    • Measuring range: Systolic pressure: 50mmHg~240mmHg, Mean pressure: 26mmHg~200mmHg, Diastolic pressure: 22mmHg~180mmHg

    • Alarm range: Systolic pressure: Upper limit: 48mmHg~240mmHg, Lower limit: 46mmHg~238mmHg

    • Mean pressure: Upper limit: 26mmHg~200mmHg, Lower limit: 24mmHg~198mmHg

    • Diastolic pressure: Upper limit : 22mmHg~180mmHg,Lower limit: 20mmHg~178mmHg


    Temperature
     
    • Measuring range: 34.0~43.0

    • Measurement error: ≤±1

    • Resolution: ± 0.1

    • Alarm range: upper limit: 36.0~43.0,lower limit: 34.0~36.0


    Alarm

    the monitor can set alarm for all monitoring parameters, it can set the alarm with sound and light. It can also cancel the alarm.

    Other

    • Power supply: AC 220V±10%,50Hz±1Hz

    • Power: 80VA

    • Display: CRT display

    • Working condition: temperature: 5~40

    • Relative humidity: ≤85%

    • Atmospheric pressure:86kPa~106kPa

     