MM-C002 Patient Monitor

Products Patient Monitor System MM-C002 Patient Monitor


MM-C002 Patient Monitor
Features:

  • Super thin (6cm), hanging wall design.

  • Application of embedded system and high integrated intelligent modular technology.

  • Patient information management function such as patient ID, age, sex, ward No, etc.

  • Digital monitoring with powerful functions.

  • Low power consumption and low malfunction rate.

  • Automatic saving after sudden power-off.

  • 12.1”or 15” high resolution TFT display with 9 waveforms.

  • Selectable 9 modes of presentation, large font, graphic displaying of 7 leads in full screen.

  • ST segment, 23 kinds of arrhythmia analysis, auto detection of lead drop.

  • Memory and playback function of ECG waveforms.

  • 720 hours of Trend graph display.

  • Memory of 2880 groups of NIBP data.

  • Function of Oxy-CRG analysis.

  • Unique modes of direct, reverse or quick measuring, applicable for adult, infant and neonate.

  • Function of overload protection.

  • Anti high-frequency electro tome and defibrillate interference, can be used with pace-maker.

  • Nurse-call function.

  • Net-work function.

  • Standard ECG, NIBP, SPO2, RESP, TEMP, PR.

  • Option Belt-in thermal recorder, Dual-IBP, EtCo2.


Specification:

Size and Weight

  • Size: 560*305*450mm

  • Weight: 5.2kgd(net), 10.5(gross)


Recorder

  • Built-in, thermal array

  • Recording mode: manual, alarm and timing

  • Parameter alarm recording

  • Waveform freeze recording

  • Trend list/graph recording

  • Alarm event review recording

  • NIBP review recording

  • Monitor information recording


Display

  • 12.1” or 15” TFT, 800*600

  • Maximum 9 waveforms in full screen

  • Power/standby indicator and battery indicator


Recall

  • Trend recall: 720hours, I-minute resolution

  • Alarm event recall: all parameters

  • NIBP measurement recall: 1400 NIBP measurement data


Battery

  • Rechargeable 12V Acid battery

  • Regular working time above 2 hours

  • Lasting 5 minutes after first alarm of low battery

  • AC power supply: 85-260V 50-60Hz ±10%


Environment

  • Operating Temperature 5~40°C Humidity = 80%

  • Storage Temperature -20~55°C Humidity = 93%


ECG

  • Displaying graphics of 7 leads on the same screen.

  • Overload protection Defibrillation.

  • Anti the interference of high-frequency electrotome

  • Lead: 5 leads (RA, LA, V, RL, LL)
  • Lead Selection: I; II; III; avR; avL; avF; V;

  • Waveform:7 channels

  • Gain Selection: ×0. 5; ×1; ×2; ×4

  • Electrical Leakage: < 30uA

  • Baseline Recovery Time: <3 sec following defibrillation.

  • Protection: separates and withstands, 4000V AC/50Hz defibrillation, resistent to interference of electrotonus and myoelectricity.

  • Scan Speed:12.5mm/25mm/50mm/sec

  • Lead Drop: Auto detection

  • Modes: DIA 0.05~100Hz,
  • MON 0.5~35Hz, OPE 1~25Hz


RESP

  • Model: RA-LL impedance

  • Measurement /alarm range:1—99 rpm

  • Resolution:1rpm.

  • Accuracy: ±2rpm.


NIBP

  • Unique Direct, Reverse and Quick modes

  • Method: automatic oscillometric

  • Working Mode: Auto/Manual

  • Interval of Auto Mode:1-60 min

  • PR Range: 0-300 bpm

  • Measurement Unit: mmHg/Kpa Selectable

  • Measurement Ranges: Systolic BP,

  • Diastolic BP and Mean BP

  • Applicability: Adult/Pediatric/Neonatal

  • Overload protection: Dual security protection


SPO2

  • SPO2probe of high intensity and durability

  • Ecellent measurement of low
  • perfusion.
  • Anti interference of movement

  • Measurement Range: 0-100%

  • Alarm range: 0-100%

  • Resolution: ±1%

  • Accuracy: ±2% (80-100%);±3% (60-79%)

  • PR range: 0~300bpm


HR

  • Measurement Range: 0-300bpm

  • Accuracy: ±1bpm or ±2%

  • Resolution: 1bpm

  • ECG Calibration: 1mV (Peak Value)

  • ST Segment offset (Diagnose Mode)

  • Measurement Range: -0.8mV~2.0mV

  • Accuracy: ±0.02mV or ±5%


TEMP

  • Resolution: 0.1 degrees Celsius

  • Accuracy: ±0.2 degrees Celsius

  • Channel: 2 channels

  • Average measurement Time: < 10sec

  • Alarm: Sound, light


 